Tomy ES-215 and ES-315 Autoclaves with Delayed Start Timer and Warming Cycle are completely self-contained, compact, and portable. They roll right to your workbench to give you fast, effective sterilization of media, glassware, instruments, and disposables - on the spot and on your schedule. The ES Series Autoclaves also feature three cycle of operation and Graphic Process Display.

Operation is very easy. Just select the cycle and set the temperature and time. The rest is automatic. A graphic display and audible alarm let you know the process and completion of the operation.

The ES-215 and ES-315 Autoclaves provide convenient processing of your laboratory sterilization and media preparation needs. These functional autoclaves offer three cycles of operation ranging from basic sterilization cycles to automatic warming cycles.
The eight hour warming cycle featured in the Tomy ES Series Autoclaves may be used directly following a sterilization cycle or independently to melt and keep sterile media ready for use.
To increase your convenience, these cycles may be programmed up to 99 hours in advance using the Delayed Start Timer. This feature enables you to have sterile media on hand and ready for use when you need it.
Tomy Autoclaves also spare you the initial installation costs associated with the plumbing and hard wiring of conventional autoclaves because they are portable. Just plug in the power cord, add water, and let the self-contained steam generator and venting system do the rest.
Tomy's vertical loading autoclaves accommodate a wide range of items. Small items like petrie dishes and test tubes are easily accommodated in the stacking baskets while large items like a fermenter or a 25 liter carboy may are also available for sterilizing liquids. To ensure your safety and complete sterilization, Tomy Autoclaves are equipped with independent temperature and pressure monitoring system.

 

Model ES-215 ES-315
Chamber Capacity 22 liters 53 liters
Operating Temperature 105 to 123degree Celsius 105 to 132degree Celsius
Temperature control Microprocessor Control
Temperature Increments 1degree
Temperature Display Type Digital
Pressure Display Range 0 to 2.0 Kgf/sq. cm 0 to 3.5 Kgf/sq. cm
Pressure Display Type Analog
Maximum Operating Pressure 1.5Kgf/sq. cm 2.2Kgf/sq. cm
Sterilization Heat Source Stainless steel electric heater, 1.5Kw Stainless steel electric heater, 2.0Kw
Time Display 1 to 240minutes, and continuous(Sterilization Cycle)
1 to 8 hours(Warming Cycle)
Dimensions 400W x 460D x 920H mm 490W x 560D x 1,090H mm
Height of Worksurface 705mm 875mm
Chamber Diameter 248mm 325mm
Chamber Height 450mm 635mm
Net Weight 50Kg 80Kg
Power 110/120V,50/60Hz,15amps
220/230/240V,50/60Hz,7apms
110/120V,50/60Hz,20amps
220/230/240V,50/60Hz,10amps

http://www.digital-biology.co.jp/english/es/index.html